{"id":11765,"date":"2022-03-07T10:46:11","date_gmt":"2022-03-07T09:46:11","guid":{"rendered":"https:\/\/www.energyteam.it\/energy-consultancy-services\/power-audit\/peak-shaving\/"},"modified":"2022-07-06T12:12:37","modified_gmt":"2022-07-06T10:12:37","slug":"peak-shaving","status":"publish","type":"page","link":"https:\/\/www.energyteam.it\/en\/energy-consultancy-services\/power-audit\/peak-shaving\/","title":{"rendered":"Peak Shaving"},"content":{"rendered":"\n<p>Management of peak demand through an automatic load-activation system enables better planning and management for the entire electricity grid, generating an immediate benefit in the form of lower costs on bills and reliability of electricity supplies.<\/p>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 43%\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/www.energyteam.it\/wp-content\/uploads\/2021\/01\/power-quality-audit-1024x683.jpg\" alt=\"\" class=\"wp-image-5126 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Peak shaving analysis enables assessment of the impact of peak demand charges on company energy spending, calculation of energy spending due to specific peaks in consumption and the proposal of a series of strategies to level out peaks and reduce costs.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Peak-demand charges on bills represent <strong>5\u201320%<\/strong> of the total and are calculated based on the maximum power peak recorded within quarter-hour slots of monthly consumption. This means that <strong>it only takes one quarter-hour period in the month<\/strong> (1 out of 2,976) with a figure above the average value <strong>to end up with a higher bill<\/strong><\/strong><\/p>\n\n\n\n<p>The annual cost for the peak demand charge component varies depending on the incentive category of <strong>power-intensive users<\/strong>:<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>\u20ac\/MW\/year<\/strong><\/td><td><strong>FAT.0<\/strong><\/td><td><strong>FAT.1<\/strong><\/td><td><strong>FAT.2<\/strong><\/td><td><strong>FAT.3<\/strong><\/td><td><strong>VAL<\/strong><\/td><\/tr><tr><td>MT \u2013 Users with P&gt;500 kW<\/td><td>50,406<\/td><td>42,639<\/td><td>40,452<\/td><td>38,265<\/td><td>34,913<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"has-primary-color has-text-color wp-block-heading\">How can peak-demand charges be reduced while maintaining production levels high?<\/h2>\n\n\n\n<p>With over 25 years of experience, Energy Team offers a comprehensive solution aimed at reducing at least <strong>8\u201315%<\/strong> of the power peak<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong><strong><strong>Reducing the power peak by just 200 kW corresponds to a saving of approximately \u20ac&nbsp;10,000 per year<\/strong><\/strong><\/strong><\/h4>\n\n\n\n<p>The 4-steps solution:<\/p>\n\n\n<section id=\"et_icons-block_600a88f76f0ae\" class=\"row et_icons justify-content-start mb-0\">\n<div class=\"col-auto d-flex mr-5 mb-3\"><div class=\"rounded-circle mr-2 p-2 bg-white rounded-circle shadow\"><img decoding=\"async\" src=\"https:\/\/www.energyteam.it\/wp-content\/uploads\/2022\/04\/Analisi-strategie.png\" style=\"width:60px;height:auto;display:block;\"><\/div><p class=\"h5 font-400 text-darker h-auto my-auto pl-2 border-left border-primary\" style=\"border-left-width: 2px !important;\">MODELLING<\/p><\/div><\/section>\n\n\n\n<p>Creation of <strong>company power-usage models<\/strong> and <strong>individual loads<\/strong> that contribute to generating the peak. The model is created using software specially developed to correlate different parameters contributing to overall company consumption. This utilises a <strong>data science<\/strong> approach to simulate real effects.<\/p>\n\n\n<section id=\"et_icons-block_600a9a776f0b0\" class=\"row et_icons justify-content-start mb-0\">\n<div class=\"col-auto d-flex mr-5 mb-3\"><div class=\"rounded-circle mr-2 p-2 bg-white rounded-circle shadow\"><img decoding=\"async\" src=\"https:\/\/www.energyteam.it\/wp-content\/uploads\/2022\/04\/Customizzazione.png\" style=\"width:60px;height:auto;display:block;\"><\/div><p class=\"h5 font-400 text-darker h-auto my-auto pl-2 border-left border-primary\" style=\"border-left-width: 2px !important;\">CUSTOMISATION<\/p><\/div><\/section>\n\n\n\n<p>The model created, with the addition of the parameters of maximum disconnection time for each user, enables assessment of the <strong>behaviour<\/strong> <strong>of the<\/strong> <strong>load-management system<\/strong> based on the power targets, simulating and evaluating all possible scenarios with complete security.<\/p>\n\n\n<section id=\"et_icons-block_600a9b196f0b3\" class=\"row et_icons justify-content-start mb-0\">\n<div class=\"col-auto d-flex mr-5 mb-3\"><div class=\"rounded-circle mr-2 p-2 bg-white rounded-circle shadow\"><img decoding=\"async\" src=\"https:\/\/www.energyteam.it\/wp-content\/uploads\/2022\/04\/Analisi-costi-benefici.png\" style=\"width:60px;height:auto;display:block;\"><\/div><p class=\"h5 font-400 text-darker h-auto my-auto pl-2 border-left border-primary\" style=\"border-left-width: 2px !important;\">COST-BENEFIT ANALYSIS AND IDENTIFICATION OF MANAGEABLE POWER<\/p><\/div><\/section>\n\n\n\n<p>Once all of the possible activation scenarios have been created, the model is used to analyse <strong>possible power thresholds<\/strong>. A cost-benefit analysis is carried out for each scenario in order to generate a significant saving with minimal impacts on the process.<\/p>\n\n\n<section id=\"et_icons-block_600a9b7b6f0b5\" class=\"row et_icons justify-content-start mb-0\">\n<div class=\"col-auto d-flex mr-5 mb-3\"><div class=\"rounded-circle mr-2 p-2 bg-white rounded-circle shadow\"><img decoding=\"async\" src=\"https:\/\/www.energyteam.it\/wp-content\/uploads\/2022\/04\/Attuazione.png\" style=\"width:60px;height:auto;display:block;\"><\/div><p class=\"h5 font-400 text-darker h-auto my-auto pl-2 border-left border-primary\" style=\"border-left-width: 2px !important;\">ACTIVATION IN THE FIELD<\/p><\/div><\/section>\n\n\n\n<p><strong><strong>Optimised configuration <\/strong>of the load-management system to control loads selected for activation and triggered by the management software. Control logics identified as optimal during modelling are entered into the software, and are updated monthly based on load forecasts.<\/strong><\/p>\n\n\n<section class=\"et_hr_line mb-0\">\r\n\t<div class=\"line_wrap\">\r\n\t\t<hr class=\" border-normal\">\r\n\t<\/div>\t\t\t\r\n<\/section>\n\n\n<h2 class=\"has-primary-color has-text-color wp-block-heading\">Here is an example<\/h2>\n\n\n\n<p>We took the example of a FAT.1 iron foundry with a monthly power peak of approximately <strong>3 MW<\/strong> and peak-demand charges totalling <strong>\u20ac&nbsp;128,000.<\/strong><\/p>\n\n\n\n<p>Focusing on the greater loads present, the choice is made to analyse the <strong>two<\/strong> induction <strong>melting furnaces<\/strong> present at the facility, developing an optimised activation logic so that disconnection of the furnaces exploits the power increments and does not impact production, setting the maximum disconnection times agreed with the foundry.<\/p>\n\n\n\n<p>Different <strong>activation scenarios<\/strong> are created, which undergo cost-benefit analysis, identifying a configuration that generates a saving of approximately <strong>\u20ac&nbsp;20,000 per year<\/strong>, altering overlapping loads by a few minutes, avoiding unjustified charges. This outcome was achieved by managing loads for a few minutes in only 50 quarter-hour slots per year (50 out of 35,040 = 0.14% quarter-hour slots\/year).<\/p>\n\n\n\n<p>Having defined the implementation architecture, Energy Team supports the customer with a <a href=\"https:\/\/www.energyteam.it\/en\/energy-consultancy-services\/\" target=\"_blank\" rel=\"noreferrer noopener\">consulting service<\/a><strong> <\/strong>aimed at identifying the <strong>optimal activation threshold <\/strong>for each month of operation.<\/p>\n\n\n\n<p>This threshold is calculated monthly on the basis of historical performance and forecasted production for the following month, in order to optimise the effectiveness of the system and <strong>maximise savings<\/strong>.<\/p>\n\n\n\n<p>The system is engineered entirely by Energy Team and enables maximum flexibility in the implementation of load-control logics.<\/p>\n\n\n\n<ul class=\"et_square wp-block-list\"><li>Instant reading of power usage through synchronisation with the distributor\u2019s meter.<\/li><li>Creation of planned power-usage curve.<\/li><li>Management of loads if the available energy is to be exceeded in the integration period analysed.<\/li><li>Constant fine-tuning of the optimal power threshold and load-modulation logics.<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Management of peak demand through an automatic load-activation system enables better planning and management for the entire electricity grid, generating an immediate benefit in the form of lower costs on [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":10288,"parent":2621,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_relevanssi_hide_post":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"6389,5808,8797,3176,3272,3076","_relevanssi_noindex_reason":"","footnotes":""},"class_list":["post-11765","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/pages\/11765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/comments?post=11765"}],"version-history":[{"count":2,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/pages\/11765\/revisions"}],"predecessor-version":[{"id":11772,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/pages\/11765\/revisions\/11772"}],"up":[{"embeddable":true,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/pages\/2621"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/media\/10288"}],"wp:attachment":[{"href":"https:\/\/www.energyteam.it\/en\/wp-json\/wp\/v2\/media?parent=11765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}